Highly-sensitive and anti-interferential electrochemical determination of hazardous metronidazole using w-NiSO4·NiS2 coated ZIF-67-derived cobalt/nitrogen-doped carbon
Yanan Pan a, 1, Duozhe Chen a,1, Yang Fan a, Jiabao Zuo a, Qi Yang a, Fan Qiu a, Lili Qiu b, Haiou Song c, Shupeng Zhang a, *
Abstract
Metronidazole (MNZ) is non-biodegradable and highly soluble in water, it is easy to accumulate in the aquatic environment, which has toxic effects in clinical applications such as causing peripheral neuritis, cardiogenic shock and pseudomembranous colitis. In this paper, Co/NC@w-NiSO4·NiS2 nanospheres were successfully constructed by coating w-NiSO4·NiS2 on the surface of ZIF-67 as the growth substrate via hydrothermal method and subsequent calcination for electrochemical detection of metronidazole (MNZ). The nanostructure and composition of the materials were confirmed by SEM, TEM, FT-IR and XPS. The sensitivity of Co/NC@w-NiSO4·NiS2 sensor for MNZ detection is 1977.14 μA/(mM·cm2); the limit of detection (LOD) is as low as 0.009 μM and the linear range is 1 ~ 200 and 200 ~ 1000 μM. Moreover, the modified sensor can resist the interference from many traditional living substances, and has good reproducibility and stability. High catalytic activity requires effective molecular transport and exposure of active sites. The successful construction of Co/NC@w-NiSO4·NiS2 nanostructure promotes the dispersion of materials and the migration of reactants on the electrode surface, and the w-NiSO4·NiS2 coating on the irregular particles of ZIF-67-derived cobalt/nitrogen-doped carbon suppressed the stacking of the w-NiSO4·NiS2 nanosheets to expose more catalytic sites. These factors are conducive to increasing the catalytic activity of the modified sensor for highly sensitive MNZ detection and ensuring the activity of catalyst in multiple catalytic cycles.
In summary, we have developed a novel electrochemical sensor for the determination of metronidazole based on Co/NC@w-NiSO4·NiS2 modified glassy carbon electrode. The electrical analysis performance of the proposed sensor is evaluated in detail. Experimental results show that the sensor has good selectivity and high sensitivity for MNZ detection, wide linear range and high resistance to common potential interfering substances. In addition, the experimental results show that Co/NC@w-NiSO4·NiS2 modified glassy carbon electrode has good reproducibility and stability. Based on the above excellent performance, the sensor can be successfully used for the efficient determination of metronidazole in pharmaceutical and biological samples. The w-NiSO4·NiS2 coated on ZIF-67-derived carbon particles inhibits the stacking of w-NiSO4·NiS2 nanosheets, exposing more catalytic sites, promoting the dispersion of materials and the migration of reactants on the electrode surface, and increasing the catalytic activity of MNZ reduction.
原文链接: https://www.sciencedirect.com/science/article/pii/S0927775723003771
Archiver|手机版|科学网 ( 京ICP备07017567号-12 )
GMT+8, 2025-1-10 14:15
Powered by ScienceNet.cn
Copyright © 2007- 中国科学报社