||
The purpose of this study was to estimate the diagnostic performance of synovial fluid polymerase chain reaction (PCR) in periprosthetic hip and knee infection, and whether synovial fluid PCR has greater diagnostic significance than conventional methods.
The literature databases PubMed, Scopus, and the Web of Science were searched for English articles describing periprosthetic joint infection (PJI) diagnosis by synovial fluid PCR. Articles were limited to the period between January 1990 and December 2019. Subsequently, conventional methods that were used on at least two occasions were included for further analysis. Data analysis was performed using the Meta-DiSc and Stata software.
Eleven studies with 1360 cases were included in the meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) of synovial fluid PCR were 0.70 (95% CI 0.66–0.74), 0.92 (95% CI 0.90–0.93), and 37.4 (95% CI 17.77–78.74), respectively.
Synovial fluid PCR provides an effective tool for rapid diagnosis of PJI, and also in the early stages of culture-negative bacterial infections.
Li, C., Li, H., Yang, X. et al. Meta-analysis of synovial fluid polymerase chain reaction for diagnosing periprosthetic hip and knee infection. J Orthop Surg Res 17, 3 (2022). https://doi.org/10.1186/s13018-021-02813-8
Archiver|手机版|科学网 ( 京ICP备07017567号-12 )
GMT+8, 2024-12-2 16:38
Powered by ScienceNet.cn
Copyright © 2007- 中国科学报社