官方给的做法,
见:http://cms.mpi.univie.ac.at/vasp-forum/forum_viewtopic.php?4.6633.0,admin给的回复,具体如下:
band structures using hybrid functionals have to be calculated thefollowing way:
-) First perform a selfconsistent Hartree-Fock/HSE calculationusing a conventional KPOINTS file.
-) Copy the IBZKPT file to KPOINTS, and explicitely add all desiredk-points along high-symmetry lines of the BZ that are needed for thebandstructure plot. Add the points at the end of the KPOINTS file, but set theweights of these added k-points to 0. (KPOINTS设置)
-) Do not forget to set the number of k-points in KPOINTS correctly(to the number of the k-points used in the standard mesh PLUS the number of thek-points along the lines), such that all k-points are used for thecalculations.
-) NKRED can not be used.
-) Perform a second VASP run:
It is recommended to use the Davidson algorithm, since it convergesthat eigen-energies at the new k-points fastest. Since VASP terminates when thetotal energy is converged to a certain threshold, it is important to force VASPto do a minimum number of steps, so that the orbitals at the new k-points arefully converged (note: since their weight is zero, they do not contribute tothe total energy).
This can be done using e.g.
ALGO = N ; NELMIN = 5 ! Davidson, minimum 5 scf-steps
IBRION = 1 ! Use simple charge mixer, since Pulay might blow up
-) The KS-eigenvalues of the states along the high-symmetry linesare written in OUTCAR, EIGENVAL, vasprun.xml; please cut the k-points requiredfor the bandstructure from one of these files and proceed as usual (usingp4vasp or any other graphics tool you usually use to producebandstructure-plots)
Note: A Hartee-Fock calculation can NOT be continued from anexisting CHGCAR file, since the non-local exchange is not determined by thecharge density but by the density matrix and/or the KS-orbitals.
个人总结:
第一步:HSE自洽计算,传统KPOINTS;
第二步:HSE能带计算,
KPOINTS设置: 传统K点末尾加上高对称点,高对称点权重为0,设置好K点权重;
INCAR:
1,不使用NKRED;
2,不能使用前一步的CHGCAR
计算结束后从OUTCAR,EIGENVAL中提取能带数据;
不解:
1,红色字体部分,设置ALGO=N之后,还怎么进行HSE计算,HSE计算需要设置ALGO=All或Damped;
2,计算后能带乱;