江苏徐州高绪仁膝肩髋关节网分享 http://blog.sciencenet.cn/u/GaoXurenKnee 膝肩髋关节关节镜、关节置换、截骨矫形方向专攻

博文

20140712徐州肩关节研究所肩关节镜Journal Club

已有 3047 次阅读 2014-7-11 00:53 |个人分类:肩关节|系统分类:论文交流| 高绪仁, institute, shoulder, Xuzhou, 徐州肩关节研究所

20140712徐州肩关节研究所Journal Club

Xuzhou Shoulder Institute Journal Club

 

时间:201471218:00-22:00

地点:江苏省徐州市淮海西路99号徐州医学院附属医院新病房大楼9楼北区骨科 徐州肩关节研究所

主讲:高绪仁  Dr.Xuren Gao  Xuzhou Shoulder Institute

内容:

1

2014 May 13;6(2):5279. doi: 10.4081/or.2014.5279. eCollection 2014.

The global percutaneous shuttling technique tip for arthroscopic rotator cuff repair.

Abstract

Most arthroscopic rotator cuff repairs utilize suture passing devices placed through arthroscopic cannulas. These devices are limited by the size of the passing device where the suture is passed through the tendon. An alternative technique has been used in the senior author's practice for the past ten years, where sutures are placed through the rotator cuff tendon using percutaneous passing devices. This technique, dubbed the global percutaneous shuttling technique of rotator cuff repair, affords the placement of sutures from nearly any angle and location in the shoulder, and has the potential advantage of larger suture bites through the tendon edge. These advantages may increase the area of tendon available to compress to the rotator cuff footprint and improve tendon healing and outcomes. The aim of this study is to describe the global percutaneous shuttling (GPS) technique and report our results using this method. The GPS technique can be used for any full thickness rotator cuff tear and is particularly useful for massive cuff tears with poor tissue quality. We recently followed up 22 patients with an average follow up of 32 months to validate its usefulness. American Shoulder and Elbow Surgeons scores improved significantly from 37 preoperatively to 90 postoperatively (P<0.0001). This data supports the use of the GPS technique for arthroscopic rotator cuff repair. Further biomechanical studies are currently being performed to assess the improvements in tendon footprint area with this technique.

KEYWORDS:

arthroscopy; percutaneous; rotator cuff repair


2

2014 Jul 8. [Epub ahead of print]

Time-dependent Changes After Latissimus Dorsi Transfer: Tenodesis or Tendon Transfer?

Abstract
BACKGROUND:

Transfer of the latissimus dorsi tendon to the posterosuperior part of the rotator cuff is an option in active patients with massive rotator cuff tears to restore shoulder elevation and external rotation. However, it is unknown whether this treatment prevents progression of cuff tear arthropathy.

QUESTIONS/PURPOSES:

The purpose of this study was to determine whether the observed improvement in shoulder function in the early postoperative period with latissimus dorsi tendon transfer for irreparable rotator cuff tears will be permanent or will deteriorate in the midterm period (at 1-5 years after surgery).

METHODS:

During a 6-year period, we performed 11 latissimus dorsi tendon transfers in 11 patients for patients with massive, irreparable, chronic tears of the posterosuperior part of the rotator cuff (defined as > 5 cm supraspinatus and infraspinatus tendon tears with Goutallier Grade 3 to 4 fatty infiltration on MRI), for patients who were younger than 65 years of age, and had high functional demands and intact subscapularis function. No patients were lost to followup; minimum followup was 12 months (median, 33 months; range, 12-62 months). The mean patient age was 55 years (median, 53 years; range, 47-65 years). Shoulder forward elevation, external rotation, and Constant-Murley and American Shoulder and Elbow Surgeons scores were assessed. Pain was assessed by a 0- to 10-point visual analog scale. Acromiohumeral distance and cuff tear arthropathy (staged according to the Hamada classification) were evaluated on radiographs.

RESULTS:

Shoulder forward elevation, external rotation, Constant-Murley scores, and American Shoulder and Elbow Surgeons scores improved at 6 months. However, although shoulder motion values and Constant-Murley scores remained unchanged between the 6-month and latest evaluations, American Shoulder and Elbow Surgeons scores decreased in this period (median, 71; range, 33-88 versus median, 68; range, 33-85; p = 0.009). Visual analog scale scores improved between the preoperative and 6-month evaluations but then worsened (representing worse pain) between the 6-month and latest evaluations (median, 2; range, 0-5 versus median, 2; range, 1-6; p = 0.034), but scores at latest followup were still lower than preoperative values (median, 7; range, 4-8; p = 0.003). Although acromiohumeral distance values were increased at 6 months (median, 8 mm; range, 6-10 mm; p = 0.023), the values at latest followup (median, 8 mm; range, 5-10 mm) were no different from the preoperative ones (mean, 7 mm; range, 6-9 mm; p > 0.05). According to Hamada classification, all patients were Grade 1 both pre- and postoperatively, except one who was Grade 3 at latest followup.

CONCLUSIONS:

The latissimus dorsi tendon transfer may improve shoulder function in irreparable massive rotator cuff tears. However, because the tenodesis effect loses its strength with time, progression of the arthropathy should be expected over time. Nevertheless, latissimus dorsi tendon transfer may help to delay the need for reverse shoulder arthroplasty for these patients.

LEVEL OF EVIDENCE:

Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.


3

2014 Jul 8. [Epub ahead of print]

Are occupational repetitive movements of the upper arm associated with rotator cuff calcific tendinopathies?

Abstract

Calcifying tendinopathy (CT) of the shoulder is a common painful disorder, although the etiology and pathogenesis remain largely unknown. Recent theories about the role of excessive mechanical load in the genesis of CT have been proposed. Driven by the interest for these new theories, we investigated the hypothesis of a relationship between work-related repetitive movements of the upper arm, considered a potential cause of shoulder overload, and the presence of shoulder CT. A secondary aim was to obtain data on CT prevalence in a female sample from the working-age general population, as little data currently exist. 199 supermarket cashiers and 304 female volunteers recruited from the general population underwent a high-resolution ultrasonography of the rotator cuffs of both shoulders, and the presence of tendinopathies, with or without calcification, was recorded. The prevalence of calcific tendinopathy was 22.6 % in the cashiers group and 24.4 % in the control group. There were no statistically significant differences in the prevalence of calcifications between the two groups (p = 0.585), either for the dominant shoulder [OR = 0.841 (95 % CI 0.534-1.326)] or for the non-dominant shoulder [OR = 0.988 (95 % CI 0.582-1.326)]. We observed bilateral calcifications in 8.5 % of cashiers, and 9.6 % of controls, and an increase in prevalence of CT with age in both groups. Work-related repetitive movements of the upper arm did not induce a higher prevalence of shoulder CT compared with the female sample from the general population. If CT etiopathogenesis is related to mechanical load, CT onset may be influenced not only by loading history, but also by individual factors. Level of evidence Prognosis study, Level II.


4

2014 Jul 4. pii: S0749-8063(14)00436-8. doi: 10.1016/j.arthro.2014.05.008. [Epub ahead of print]

Outcomes of Arthroscopic Anterior Shoulder Instability in the Beach Chair Versus Lateral Decubitus Position: A Systematic Review and Meta-Regression Analysis.

AbstractPURPOSE:

This study aimed to systematically review the clinical outcomes and recurrence rates after arthroscopic anterior shoulder stabilization in the beach chair (BC) and lateral decubitus (LD) positions.

METHODS:

The authors performed a systematic review of multiple medical databases using Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. All English-language literature from 1990 to 2013 reporting clinical outcomes after arthroscopic anterior shoulder stabilization with suture anchors or tacks with a minimum 2-year follow-up period were reviewed by 2 independent reviewers. Data on recurrent instability rate, return to activity/sport, range of motion, and subjective outcome measures were collected. Study methodological quality was evaluated with the Modified Coleman Methodology Score (MCMS) and the Quality Appraisal Tool (QAT). To quantify the structured review of observational data, meta-analytic statistical methods were used.

RESULTS:

Sixty-four studies (38 BC position, 26 LD position) met inclusion criteria. A total of 3,668 shoulders were included, with 2,211 of patients in the BC position (average age, 26.7 ± 3.8 years; 84.5% male sex) and 1,457 patients in the LD position (average age, 26.0 ± 3.0 years; 82.7% male sex). The average follow-up was 49.8 ± 29.5 months in the BC group compared with 38.7 ± 23.3 months in the LD group. Average overall recurrent instability rates were 14.65 ± 8.4% in the BC group (range, 0% to 38%) compared with 8.5% ± 7.1% in the LD group (range, 0% to 30%; P = .002). The average postoperative loss in external rotation motion (in abduction) was reported in 19 studies in the BC group and in13 studies in the LD group, with an average loss of 2.4° ± 1.0° and 3.6° ± 2.6° in each group, respectively (P > .05).

CONCLUSIONS:

Excellent clinical outcomes with low recurrence rates can be obtained after arthroscopic anterior shoulder stabilization in either the BC or the LD position; however, lower recurrence rates are noted in the LD position. Additional long-term randomized clinical trials comparing these positions are needed to better understand the potential advantages and disadvantages of each position.

LEVEL OF EVIDENCE:

Level IV, systematic review of studies with Level I through Level IV evidence.


5

2014 Jun 30;14:50. doi: 10.1186/1471-2253-14-50. eCollection 2014.

Blood pressure response to combined general anaesthesia/interscalene brachial plexus block for outpatient shoulder arthroscopy.

Abstract
BACKGROUND:

Shoulder surgery is often performed in the beach-chair position, a position associated with arterial hypotension and subsequent risk of cerebral ischaemia. It can be performed under general anaesthesia or with an interscalene brachial plexus block, each of which has specific advantages but also specific negative effects on blood pressure control. It would be worthwhile to combine the advantages of the two, but the effects of the combination on the circulation are not well investigated. We studied blood pressure, heart rate, and incidence of adverse circulatory events in patients undergoing shoulder surgery in general anaesthesia with or without an interscalene block.

METHODS:

Prospective, randomised, blinded study in outpatients (age 18 to 80 years) undergoing shoulder arthroscopy. General anaesthesia was with propofol/opioid, interscalene block with 40 ml 1% mepivacaine. Hypotension requiring treatment was defined as a mean arterial pressure <60 mmHg or a systolic pressure <80% of baseline; relevant bradycardia was a heart rate <50 bpm with a decrease in blood pressure.

RESULTS:

Forty-two patients had general anaesthesia alone, 41 had general anaesthesia plus interscalene block. The average systolic blood pressure under anaesthesia in the beach-chair position was 114 ± 7.3 vs. 116 ± 8.3 mmHg (p = 0.09; all comparisons General vs. General-Regional). The incidence of a mean arterial pressure under 60 mmHg or a decrease in systolic pressure of more than 20% from baseline was 64% vs. 76% (p = 0.45). The number of patients with a heart rate lower than 50 and a concomitant blood pressure decrease was 8 vs. 5 (p = 0.30).

CONCLUSION:

One can safely combine interscalene block with general anaesthesia for surgery in the beach-chair position in ASA I and II patients.

CLINICAL TRIAL NUMBER:

DRKS00005295.




欢迎您的参加和讨论!



https://blog.sciencenet.cn/blog-394169-810737.html

上一篇:20140710徐州肩关节研究所肩关节镜Journal Club
下一篇:20140714徐州肩关节研究所肩关节镜Journal Club
收藏 IP: 180.104.235.*| 热度|

1 Vetaren11

该博文允许注册用户评论 请点击登录 评论 (0 个评论)

数据加载中...
扫一扫,分享此博文

Archiver|手机版|科学网 ( 京ICP备07017567号-12 )

GMT+8, 2024-10-20 13:29

Powered by ScienceNet.cn

Copyright © 2007- 中国科学报社

返回顶部