选用

1/4'stainless metal pipe (6-metre-long)

three-way tube fitting for 1/4'tubings (Hoke, Gyrolok, flareless tube fittings)

two way valves

pipe clamp, diameter 6.4mm,(farnell,120-2528)

Three parallel pipes with distance of 15cm each other.

The location of connections are close to the electricity plug.

The connections on different pipe should have a distance of 10 cm to each other.

To avoid the damagement on lab wall, a wash is employed with the pipe clamp with 1 cm in length.

In the corner, a distance between wall and pipe is equal to the length of a wash.


Spacer is used in between pipe and wall.

Inner Diameter should be just bigger than that of screw.

Length is 5-10 mm.(Farneel, R40F6710594, Harwin)



 

Pen-ray lamp (Hg/Ar)

Lot Lsp035

www.lot-oriel.com

info@LOT-oriel.de


stripboard, farnell, 147899

Spot Face Cutter, farnell,329538

 